wind_sensor:meeting_minutes_may_19_2017

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Next revision
Previous revision
Next revision Both sides next revision
wind_sensor:meeting_minutes_may_19_2017 [2017/05/20 00:29]
mwu created
wind_sensor:meeting_minutes_may_19_2017 [2017/05/20 01:12]
mwu [Ultrasonic Wind Sensor]
Line 5: Line 5:
 =====Ultrasonic Wind Sensor===== =====Ultrasonic Wind Sensor=====
   * Updates:   * Updates:
-    * Implemented non-inverting amplifier with DC bias. Currently attempting to send just one pulse, so using a gain of about 110 V/V.+    * Implemented non-inverting amplifier with DC bias. Currently attempting to send just one pulse, so using a gain of about 110 V/V. {{ :​wind_sensor:​one_pulse_amplifier.jpg?​direct&​600 |}} 
 +      * The disadvantage to having this amplifier is that the noise is also amplified which causes the voltage comparator to trigger falsely. 
 +    * Attempted to use the Schmitt Trigger to "​qualify"​ the signal before registering it as a valid response. 
 +      * The trigger'​s threshold levels were experimentally determined to be: Vth = 1.95V, Vtl = 1.15V. The idea was to center the signal at one of the thresholds and use the other threshold as the trigger. This would'​ve solved the issue since the signal would have to satisfy one threshold before it changes the output of the trigger (qualification). 
 +      * The signal was centered at 1.95V, but the result was inconsistent. Sometimes the signal would register while other times it wouldn'​t.
   * To Do:   * To Do:
  • wind_sensor/meeting_minutes_may_19_2017.txt
  • Last modified: 2021/09/19 21:59
  • (external edit)