mwu [Ultrasonic Wind Sensor]
wind_sensor:meeting_minutes_apr_14_2017 [2021/09/19 21:59] (current)
Line 3: Line 3:
 =====Acoustic Wind Sensor===== =====Acoustic Wind Sensor=====
   * Updates:   * Updates:
 +    * Met with Dr. Kuh to discuss current status of project
 +      * Working real time processing algorithm to obtain wind speed of a single microphone
 +      * Algorithm to determine direction
 +        * Works for only 90 degrees
 +    * Conducted tests between 0 and 90 degrees to determine wind speed and direction in indoor conditions
 +      * Used an anemometer to calibrate wind speed
 +      * Used a lazy susan marked with angles 0 to 360 degrees to calibrate direction
 +      * Placed anemometer facing in the direction of the 0 degree mark and turned lazy susan to desired testing angle
   * To Do:   * To Do:
 +    * Conduct tests of algorithm beyond just 90 degrees
 +    * May require modifying algorithm. ​