wind_sensor:meeting_minutes_apr_28_2017 [2017/04/30 11:50]
mwu [Ultrasonic Wind Sensor]
wind_sensor:meeting_minutes_apr_28_2017 [2021/09/19 21:59] (current)
Line 3: Line 3:
 =====Acoustic Wind Sensor===== =====Acoustic Wind Sensor=====
   * Updates:   * Updates:
 +    * Inaccuracies in single microphone wind speed algorithm due to assumption that all microphones are set the same way
 +    * To fix this, microphones were re-calibrated individually,​ each microphone calibrated with 8 wind speeds
 +    * Peak detector coefficients were determined for each microphone ​
 +    * Raw wind direction tests were conducted from 0 to 360 degrees using the new peak detector equations ​
 +    * Peak detector outputs of each microphone with the north microphone at 0 to 360 degrees were plotted
 +    * Using this raw data, microphone angle and ratio of the two largest microphone readings at each angle were plotted
 +    * A linear relationship was derived mapping the microphone angle to this raio 
   * To Do:   * To Do:
 +    * Conduct tests to verify relationship
 +    * Look at implementing some other filters (i.e. FIR)