 =====Acoustic Wind Sensor===== =====Acoustic Wind Sensor=====
   * Updates:   * Updates:
-    * +    * Conducted additional tests to verify accuracy of moving average algorithm 
 +      * Results are slightly inconsistent. ​ For a 4 mph wind speed, the output of the code is on average 6 +/- 1 mph. 
 +      * Adding foam padding around the microphone improved results 
 +        * Detected wider range of frequencies 
 +        * Results improved to 4.5 +/- 0.1 mph 
 +    * Worked on Preliminary Design Review
   * To Do:   * To Do:
-    * +    * Recalculate coefficients with padded microphones to see if previously determined coefficients change 
 +    * Conduct additional tests
 =====Ultrasonic Wind Sensor===== =====Ultrasonic Wind Sensor=====
   * Updates:   * Updates: