=== Mesh Network Set up (Many-To-One) ===
- Configure all three remote devices
- add all three XBees (Collector, relay and router)
- update the firmware of each module
- Function Set: DigiMesh 2.4 TH PRO
- Firmware Version: Newest value
- Configuring the first device (Collector)
- First click the default parameter setting
- Then change these parameters
- ID: 7FFF
- NI: SENDER
- API: API enabled [1]
- IMPORTANT: there is already an empty space in NI, so be sure to delete that before naming module
- Configuring the second device (can be the router or relay XBee)
- Click the default parameter to reset parameters
- Change parameters to:
- ID: 7FF
- NI: Relay_1
- API: Transparent Mode [0] ( or you cand do 1, we just left it at 0)
- Write the radio settings
- Configure the third device exactly the same as the second device. Setting NI as Relay_2
- Disconnect both the relay and router XBees and put them into their own power supply (we used two laptops)
- Each module should be plugged into their own power supply by now
- Radio modules should only contain the coordinator now
- Using the laptop that has the coordinator, select the coordinator, and click the “discover the radio nodes in the same network
- add all selected devices (relay and router Xbees) in the discovering remote devices
=== Testing the XBees Communications ===
- Using the laptop containing the coordinator
- Using the laptop contained the router:
- Open up XCTU program and discover the router XBee