Wednesday April 6th, 2022
Members present: Roel, Alex, Juliana, Kayla
- populated another Rev DII board
- need to label value of R10 as 270kohm
Thursday April 7th, 2022
Members present: Alex, Marvin, Donovan, Juliana
- 296 (Elle and Dylan) shadowed
- bootloaded and tested new Rev DII board
- Declared blue dot board as dysfunctional; do not continue testing with it
- Breaking the connection on the PCB to Vboard (free floating) causes battery and solar panel voltages to result in incorrect readings
- using the voltage divider: battery voltage results in about 3.3V
- need to bring value below Vcc
Authors
Contributing authors:
Created by changjul on 2022/04/07 02:27.